3/03/23 Lewis Integrative Science Building Rooms 142, 145 -152 Electrical Shutdown

Begin:  Friday, March 3, 2023, at 7:00 am

End:      Friday, March 3, 2023, at 10:00 am

Building(s) or Area(s) Affected:  Lewis Integrative Science Building – Rooms affected per drawing: 142, 145, 146, 147, 148, 149, 150, 151, 152

Scope:  CPFM Facilities crew will replace a relay in the mezzanine.  Power will be shut off to CKT#10 in PNL BN2-4 (located in basement), which supplies lighting to multiple rooms – see attachment for details.

Services Impacted:  Power will be off during this time.

Work Performed By:  CPFM FS BAS Dept.

ContactWork Control Center, Campus Planning and Facilities Management, 541-346-2319

Current construction and impacts information can be found on the UO Maps site.

2/18/23 Huestis Basement and Lokey Labs Electrical Shutdown

UPDATE:
The shutdown was not able to be completed as scheduled.  The work described below has been rescheduled for Saturday, February 18.

 

Begin:  Saturday, February 04  18, 2023, at 7:00 am

End:      Saturday, February 04  18, 2023, at 12:00 noon

Building(s) or Area(s) Affected:  Huestis Basement and Lokey Labs

Scope:  As part of the Huestis Hall Renovation project, normal power will be offline for installation of temporary power j-boxes and electrical conduit reconfiguration in the Huestis basement. The shutdown of the 600 amp disconnect will temporarily shut down normal power to all Lokey Labs systems on panel 2N2 including heating water, and all Huestis Basement systems on panels Bn3-2, Bn4-2, Bn5-2, and Bn6-2.

Per previous shutdowns to these panels, it was determined that critical equipment is on standby power.

Services Impacted:

  • This will affect the electrical, fume hoods, heating systems, chilled water, and exhaust.
  • The work is scheduled for 5 hours on Saturday, but the shutdown is not expected to take the full duration.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Additional Instructions:  Fume hood sashes should be closed and containers within the fume hoods sealed prior to this date.

Work Performed By:  EC and Lewis

ContactMartina Oxoby, CPFM Owner’s Representative, 541-346-5880

Current construction and impacts information can be found on the UO Maps site.

Temp power shutdown 600a Basement Power E1.20 and E1.21 (1)

1/03/23 Klamath Hall Electrical Panel Shutdown

UPDATE:
Power was restored to Klamath Hall.  All electrical is back in normal status.

 

UPDATE:
The Onyx Bridge east elevator will also be down during this time.

 

Begin:  Tuesday, January 3rd, 2023, at 9:00 am

End:      Tuesday, January 3rd, 2023, at 1:00 pm

Building Affected:  Klamath Hall

Scope:  The main electrical panels will be shut down to evaluate components and test breakers after water intrusion that occurred on 12/10/22.

Services Impacted:  This will affect the electrical power, exhaust, fume hoods, heating, HVAC Air Supply, lab vacuum, and elevator.

Special Instructions:

  • Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.
  • Fume hood sashes should be closed and containers within the fume hoods sealed prior to this date.

Work Performed By:  Outside Contractor

ContactWork Control Center, Campus Planning and Facilities Management, 346-2319

To view current construction and impacts. visit UO Map.

12/27/22 – 12/30/22 Knight Library #57, 19, H57 Renovation Advisory

Begin:  Tuesday, December 27th, 2022

End:      Friday, December 30th, 2022

Building(s) or Area(s) Affected:  Knight Library Rooms 19, 57, and Hallway H57

Scope:  Abatement, demolition, and renewal will occur for rooms 19, 57, and hallway H57, while they receive new lighting, flooring, paint, and electrical.

Services Impacted:

  • ADA access will be impacted from the NW lower entrance to the elevator.
  • Construction noise and odor can be expected during this time.

Work Performed By:  PMG Demolition and CPFM Facilities Services

ContactJanell Cottam, CPFM Owner’s Representative, 541-346-7536

Current construction and impacts information can be found on the UO Maps site.

12/20/22 Campus Planned Power Testing Unexpected Service Interruption

During island mode testing, we operated a seamless transition from the EWEB power grid to Island Mode.  However, at 11:09 am, while transitioning from Island Mode back to the main grid, we experienced an unexpected momentary glitch in the system.  We are now back on stable power and will have no further testing today.  We will continue to troubleshoot the system at a future date.

We apologize for the inconvenience this has caused.  Please verify that your equipment is back up and operating as expected.

Should you need to report any issues, contact Work Control Center at 541-346-2319 or workcontrolcenter@uoregon.edu.

Current construction and impacts information can be found on the UO Maps site.

12/20/22 Campus Planned Power Testing

Begin:  Tuesday, December 20th, 2022, at 7:00 am

End:      Tuesday, December 20th, 2022, at 3:30 pm

Building(s) or Area(s) Affected:  Campus Wide

Scope:  Utilities and Energy (U&E) will start testing Island mode quarterly instead of annually. This emergency power system requires extensive service more often and complies with our service agreement with the turbine manufacturer. These tests will be during Spring break, Summer break, the annual September power testing, and Winter break. The next test will be December 20th, 2022. Most likely we will enter island mode throughout the day for testing with no exact timeframe.

Services Impacted:  This is a seamless power transition and we do not expect any impacts to campus power.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Utilities & Energy and Contractor

ContactRick Tabor, CPFM Interim Co-Dir Utilities & Energy, 541-346-7511

To view current construction and impacts, visit UO Map.

12/19/22 Feeder 1 Electrical Shutdown

Begin:  Monday, December 19th, 2022, at 7:00 am

End:    Monday, December 19th, 2022, at 8:00 am

Buildings:  Unthank Hall, Bean Hall, Global Scholars, Kalapuya Ilihi, Ford Alumni, Matt Knight Arena.

Scope:  Feeder 1 will be shut down to connect the HWTP Phase 2 Project to campus power.

Services Impacted:

  • This will affect main power and elevators, however these buildings will be on standby power during this time.
  • This will not impact Hayward Field.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Oregon Electric Group and CPFM U&E

ContactGeorge Bleekman, CPFM Owner’s Representative, 541-346-2625

Current construction and impacts can be found on the UO Maps site.

12/12/22 – 1/31/23 PLC Classroom Construction Noise Advisory

Begin:  Monday, December 12th, 2022

End:      Tuesday, January 31st, 2023

Building(s) or Area(s) Affected:  Prince Lucien Campbell Hall Rooms 348, 353, and adjacent rooms

Scope:  PLC 348 and 353 will be renovated into a single classroom

Services Impacted:  Most construction activity will be restricted to the interior of the two rooms however, some construction related noise can be expected in adjacent areas.  The bulk of the work will take place over the winter break, with less intrusive work continuing into the first weeks of winter term.

Work Performed By:  GBC Construction

ContactTim Allenbaugh, CPFM Owner’s Representative, 541-346-8214

Current construction and impacts information can be found on the UO Maps site.

12/10/22 Unexpected power outage impacting Klamath Hall and Onyx Bridge

UPDATE – #2 12/10/22 at 6:05 pm:

The power has been restored. Power is on in a single-ended condition. Power is currently being fed from feeder 10.

A contractor will be out as soon as Utilities and Energy can get them to campus to evaluate the switch.

UPDATE – 12/10/22 at 4:44 pm:

The power outage has been determined to impact all floors of Klamath Hall, including fume hoods.  Facilities and Utilities and Energy are on site. EH&S is aware and working with CPFM personnel. The Utilities and Energy Electrical supervisor is on site. The hope is to have the power restored in 3-4 hours.  The Building Automation (BAS) and Mechanical Teams are on site, ready to support the restore.

INITIAL EVENT NOTICE 12/10/22 at 2:08 pm: 

Parts of Klamath Hall and Onyx Bridge lost electrical power today (December 10). This resulted in various security and other alarms being triggered. UOPD responded to ensure the security of the facility, and Facilities Services electricians are onsite for assessment and restoration of the power situation.

The power outage is currently impacting the following:

  • Klamath Hall Basement, 1st and part of 2nd Floor
  • Onyx 1st Floor

The restore ETA is still TBD, but teams hope to achieve a power restoration by evening hours today. A restore message will be sent as soon as services are restored.

11/29/22 Pine Mountain Observatory Electrical Outage

Begin:  Tuesday, November 29th, 2022 at 10:00 am

End:      Tuesday, November 29th, 2022 at 3:00 pm

Building(s) or Area(s) Affected:  Pine Mountain Observatory

Scope:  There will be a planned power outage to allow Central Electric to do some system improvement work at their Hampton Substation.

If temperatures will be below freezing, the outage will be cancelled and rescheduled at a later date.  A call will be placed notifying Pine Mountain if the outage is taking place as scheduled or if it has been cancelled.

Services Impacted:  Power is expected to be offline for approximately 5 hours.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Central Electric Cooperative, Inc.

Contact:  Brent ten Pas, Director of Member Services and Public Relations 541-548-2144

Information on current construction and impacts can be found at UO Maps

10/13/22 Zebrafish International Resource Center Electrical Outage

Begin:  Thursday, October 13th, 2022, at 7:00 am

End:      Thursday, October 13th, 2022, at 7:30 am

Building(s) or Area(s) Impacted:  Zebrafish International Resource Center

Scope:  Building power will be offline for 30 minutes to install an electric meter .

Services Impacted:  This will impact electrical power, exhaust, and the HVAC air supply.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Fortis Construction

ContactColin Brennan, CPFM Owner’s Representative, 541-346-8242 or 541-654-2972

9/24/22 Huestis Hall Basement and Lokey Labs Electrical Shutdown

REVISED:
The shutdown has been rescheduled for Saturday, September 24th, 2022.

 

Begin:  Saturday, September 10th, September 24th, 2022 at 6:00 am

End:      Saturday, September 10th, September 24th, 2022 at 4:00 pm

Building(s) or Area(s) Affected:  Huestis Hall Basement and Lokey Labs

Scope:  Permanent shutdown of Huestis main distribution panel (MDP) to allow buildout of new construction equipment. Re-distribute power to 2N2A, BN-7, Construction temp power, and OC-2 loads from 3) new 600A fused switches to be located in transformer vault behind MDP. – see attachments

Services Impacted:  Normal power will not be available during this shutdown. Standby power will not be affected.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Lease Crutcher Lewis and EC

ContactMartina Oxoby, CPFM Owner’s Representative, 541-346-5880

To view current construction and impacts. visit UO Map.

E6.13 MDP demo schematic (1) (002)

MDP distribution plan REV2

Temp power SQD H326NR (1)

9/22/22 Huestis Basement Zebrafish Facility Electrical Shutdown

Begin:  Thursday, September 22nd, 2022 at 6:00 am

End:      Thursday, September 22nd, 2022 at 7:00 am

Building and Area:  Huestis

Scope: As part of the Huestis Hall Renovation Project, power will be shut off to the Huestis basement Zebrafish Facility for 1 hour to allow temp power to be removed from BS1-2 and install the permanent feed. Siemens will monitor equipment alarms in Aquaculture room 03.

Services Impacted:  Electrical will be offline in the Huestis basement Zebrafish Facility.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Lease Crutcher Lewis and EC

Contact: Martina Oxoby, CPFM Owner’s Representative, 541-346-5880

To view current construction and impacts. visit UO Map.

9/22/22 Huestis Basement Zebrafish Facility Rooms 3 and 10 Electrical Shutdown

Begin:  Thursday, September 22nd, 2022 at 6:00 am

End:      Thursday, September 22nd, 2022 at 7:00 am

Building and Area:  Huestis Basement Zebrafish Facility Rooms 03 and 10

Scope: As part of the Huestis Renovation project, there will be a brief shutdown of electrical panel BS1-2 for final permanent electrical connections.

Services Impacted:  This will affect the Zebrafish facility rooms 03 and 10.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  EC

Contact: Martina Oxoby, CPFM Owner’s Representative, 541-346-5880

To view current construction and impacts. visit UO Map.

9/14/22 Planned Power Outage

UPDATE:
Utilities & Energy has switched from island mode back to the normal power configuration as planned.
Please report any issues caused by the outage, including IT, to the CPFM Work Control Center at 541-346-2319,  workcontrolcenter@uoregon.edu, or by entering a service request on the UO call log https://cgis.uoregon.edu/Calllog.
Thank you.

 

 

We are writing to remind you of the upcoming annual planned power outage on Wednesday, September 14th, 2022.

In the event our campus service from the local EWEB electrical grid is interrupted, the UO Utility and Energy plant is capable of providing the campus with electricity (called Island Mode). To best ensure this system operates as designed when needed, the Utility and Energy plant now exercises this system annually. This year’s Island Mode event will take place on Wednesday, September 14, 2022, at 7:35 am. 

At 7:35 am, the entire campus will shift from the primary EWEB power source to the backup generator system at the Central Power Station, also known as “Island Mode”.

While not anticipated, some buildings may briefly lose power when the switch occurs, if a portion of the system does not perform as expected.

At 7:45 am, Feeder 1 will be de-energized.  Affected buildings will experience a  power outage lasting approximately 1 hour.  During this time Utilities and Energy staff will be disconnecting power in a vault for a switch replacement project and exchanging the feeder breaker. Crews will then ensure systems are successfully coming back online.

At 9:00 am, Feeder 10 will be de-energized.  Affected buildings will experience a power outage lasting 15 minutes. During this time Utilities and Energy staff will be exchanging the feeder breaker.  Crews will then ensure systems are successfully coming back online.

At 10:00 am, Standby feeder 2 will be de-energized. This will have no affect to the campus buildings.

At 12:00 noon, Utilities and Energy will Initiate normal power configuration.

For a detailed schedule of feeders and maps of buildings affected, visit the 2022 Power Outage webpage. Updates about the project will be posted on that page and Around the O.

Individuals who wish to request planning assistance for the outages should contact Campus Planning and Facilities Management Work Control at workcontrolcenter@uoregon.edu or 541-346-2319.

Please remember to shut down all multi-function copier devices as well as any printers. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

To view current construction and impacts. visit UO Map.

9/14/22 Lokey Labs Electrical Shutdown

Begin:  Wednesday, September 14th, 2022 at 6:00 am

End:      Wednesday, September 14th, 2022 at 7:00 am

Building and Area:  Lokey Labs

Scope: As part of the Huestis Renovation Project, there will be a brief shutdown of electrical panel 2N2 and 2N2A

Services Impacted:  This electrical outage will affect the chilled water, compressed air, power, exhaust, fume hoods, and HVAC air supply.

Special Instructions:  Fume hood sashes should be closed and containers within the fume hoods sealed prior to this date.

Additional Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Lease Crutcher Lewis and EC

Contact: Martina Oxoby, CPFM Owner’s Representative, 541-346-5880

To view current construction and impacts. visit UO Map.

8/18/22 Allen Hall Transformer Testing Electrical Shutdown

Begin: Thursday, August 18th, 2022 at 8:00 am

End:     Thursday, August 18th, 2022 till 6:00 pm

Building Impacted:  Allen Hall

Scope:

  • Due to Data center required utility transformer testing the power will be shut down

from 8:00 am -12:30 pm. Allen hall will be on Standby power during this time.

  • From 12:30 pm to 6:00 pm Allen hall will be on normal power without Standby backup.

Services Impacted:  The entire building will be affected.

Work Performed By:  Utilities and Energy and Contractor

ContactRick Tabor, CPFM Interim Co-Dir Utilities & Energy, 541-346-7511

To view current construction and impacts, visit UO Map.

5/24/22 CPFM Lock Shop Electrical Shutdown

Begin:  Tuesday, May 24th, 2022 at 7:00 am

End:      Tuesday, May 24th, 2022 at 3:30 pm

Building(s) or Area(s) Impacted:  CPFM Lock and Key Shop

Scope:  Power to the building will be shutdown to install new electrical feeders.

Services Impacted:  Electrical will be offline during this time.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Fortis Construction

ContactColin Brennan, CPFM Owner’s Representative, 541-346-8242 or 541-654-2972

5/14/22 Huestis Hall and Lokey Labs Electrical Shutdown

Begin:  May 14th, 2022 at 7:00 am

End:      May 14th, 2022 at 10:00 am

Building(s) or Area(s) Impacted:  Huestis Hall and Lokey Labs

Scope:  As part of the Huestis Hall Renovation project, the main electrical distribution panel will be shut down for installation of temp power panels and breakers.

Services Impacted:

  • In Huestis Hall, all systems and equipment connected to normal power will be affected and unavailable. Equipment on standby power will not be affected.
  • In Lokey Labs, all systems and equipment connected to normal power will be affected and unavailable. Equipment on standby power will not be affected.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Mortenson Construction / EC Electric

ContactMartina Oxoby, CPFM Owner’s Representative, 541-346-5880

Esslinger Hall & NW Corner of SRC Electrical Shutdown 4/30/22

UPDATE 4/18: The first hour (from 6am to 7am), ALL of Esslinger, and the NW corner of the Student REC Center of will be without power. After 7am, the noted spaces for Esslinger will continue to be offline until 4pm.

Begin:  Saturday, April 23rd 30th, 2022 at 6:00 am

End:      Saturday, April 23rd 30th, 2022 at 4:00 pm

Building(s) or Area(s) Impacted:  Esslinger Hall & NW Corner of SRC

Scope:  Electrical Panel C1 and C2 will be shut down to replace them with new panels. The first hour (from 6am to 7am), ALL of Esslinger, and the NW corner of the Student REC Center of will be without power. After 7am, the noted spaces for Esslinger will continue to be offline until 4pm.

Services Impacted:  Power will be off on Saturday to the NW corner of the SRC and all of Esslinger.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Mortenson Construction / EC Electric

ContactTim Allenbaugh, CPFM Owner’s Representative, 541-346-8214

Zebrafish International Resource Center Electrical Shutdown 4-07-22

Begin:  Thursday, April 07, 2022 at 5:40 am

End:   Thursday, April 07, 2022 at 6:35 am

Building(s) or Area(s) Impacted: Zebrafish International Resource Center

Scope:  Power will be shut down while circuit breakers are installed in the main distribution panel.

Services Impacted:  HVAC / Air Supply, Fume Hoods, Fire Alarm system and Electrical

Special Instructions:  Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By: Fortis Construction

Contact: Colin Brennan, CPFM Owner’s Representative, 541-346-8242 or 541-654-2972

Unthank Hall Electrical Shutdown 3/23

Begin:  March 23rd, 2022 at 8:00 AM

End:      March 23rd, 2022 at 2:00 PM

Building(s) or Area(s) Impacted:  Unthank Hall

Scope:  We will have an electrical shutdown at Unthank Hall. The building will be on standby power during the shutdown. Stand-By will power walk-in coolers, walk-in freezers, walk-in beverage coolers, ADA doors, MDF/IDF rooms, FSD’s, fire alarm system, elevator system, and all lighting that is on egress. This shutdown is to test the ATS and install a metering cabinet in the main switchgear.

Services Impacted: All electricity will be down except walk-in coolers, walk-in freezers, walk-in beverage coolers, ADA doors, MDF/IDF rooms, FSD’s, fire alarm system, elevator system, and all lighting that is on egress.

Special Instructions: Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By: Oregon Electric Group

Contact: George Bleekman, CPFM Owner’s Representative, 541-346-2625

Huestis Basement Electrical Shutdown 3-24-22

Begin:  Thursday, March, 24 at 7:00 am

End:  Thursday, March, 24 at 12:00 pm

Building(s) or Area(s) Impacted:  Huestis Hall basement.

Scope:  Normal power from panel BN5-2 will be shut down in basement lab areas

Services Impacted: Electrical power will be offline for five hours.  See attached map for areas that will be affected during this time.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Mortenson Construction / EC Electric

ContactMartina Oxoby, CPFM Owner’s Representative, 541-346-5880

Huestis Basement Electrical Shutdown 3-23-22

Begin:  Wednesday, March, 23 at 7:00 am

End:  Wednesday, March, 23 at 12:00 pm

Building(s) or Area(s) Impacted:  Huestis Hall basement.

 Scope:  Normal power will be shut down in basement lab areas due to Huestis basement renovation scope and install new feeders in to the electrical panels

Services Impacted: Electrical power will be offline for five hours.  See attached map for areas that will be affected during this time.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By:  Mortenson Construction / EC Electric

ContactMartina Oxoby, CPFM Owner’s Representative, 541-346-5880

 

 

Klamath Hall Ground Floor Electrical Shutdown 3/12/22

Begin:  Saturday, March 12, 2022 at 7:00 am

End:  Saturday, March 12, 2022 at 3:00 pm

Building(s) or Area(s) Impacted:   Klamath Hall Ground Floor – see specific rooms affected below

 Scope:   Power will be shut down to electrical panel serving portions of the Ground floor while contractors connect additional circuits for room 019.

Services Impacted:  Electrical power will be shut down to rooms 018, 019, 019A, 019B, 019C, 019D, 021, 023, 024, 030, 032, 033, 065, 065A-065C, 053, 073A, 075, 075A and the corridor lights will be off in hallways H002, H004, H005, and H006.

Special Instructions:  Please shut down and unplug all multi-function copier devices as well as any printers during scheduled power outages. The software on these machines can be negatively affected due to the power surge when the power is turned back on.  A power surge can corrupt the clone files in the machines and change preconfigured settings.

Work Performed By: Mortenson Construction, EC Electric

ContactTim Allenbaugh, CPFM Owner’s Representative, 541-346-8214