Klamath Hall Men’s Ground Floor Restroom #080 Advisory 8/12/19 – 8/23/19

Beginning Monday, August 12th through Friday, August 23rd, the men’s toilet in room #080 will have been temporarily removed to allow plumbers to access and revise waste piping.  Urinals will remain in place.

Work will be performed by Lease Crutcher Lewis.

For questions or concerns, please contact Denise Stewart at 541-335-1258 or dstewart@uoregon.edu.

 

 

ZEBRAFISH Compressed Air Shutdown 8/8/19

On Thursday, August 8th, from 7:00 am to 3:00 pm, the compressed air system in the utility tunnel will be shut down for re-routing as part of the Knight Campus Project.  The branch from the central plant to the Knight Campus site will be taken out of service, while all other locations will remain operational.  This work will take place in the tunnel.

Work will be performed by S2.

For questions or concerns, please contact Jeff Madsen at 346-2256 or jmadsen@uoregon.edu.

HEDCO Electrical Shutdown 8/31

On Saturday, August 31, CPFM Utilities and Energy will be coordinating a contractor to work on the transformer that services HEDCO.  This will require a building-wide electrical shutdown.  The electrical shutdown will begin at 9:00 am and will last approximately 6 hours.  The crew will remain on-site one hour after energizing.

 

Scope of work. Crews will de-energize the transformer and drain out the oil so the oil sampling port can be replaced.  After that, the oil will be added and then monitored for leaks to let the air bubbles rise before crews can energize. Air bubbles in the oil can cause electrical arcing inside. Crews test the oil, so they can see how the transformer is doing and predict what maintenance can/should be done to extend the life of the transformer.

 

This work was pre-coordinated with Facilities Liaison Eric Owens.

 

For questions or concerns, please contact:

 

Rick Tabor

University of Oregon

Utilities and Energy Electrical Superintendent

Campus Planning and Facilities Management

541-346-7511

CPFM Warehouse & Shop (Bldg 130) Noise Advisory and Heating Shutdown 8/12/19 – 8/19/19

Beginning Monday, August 12th at 7:00 am until Monday, August 19th at 4:00 pm, Facilities Services will be removing a number of abandoned pipes and equipment from Mechanical room #226A.  The heating system will also be shut down during this time.

The activities inside the room will be very loud as pipes are cut in place and extracted.  The noise will likely be heard throughout the building.

Additionally, a section in the fleet parking area, just south of the building, will be marked off where a forklift will be parked to take away the debris from the second story.

For questions or concerns, please contact Tim Allenbaugh at 346-8214 or timallen@uoregon.edu.

 

Lillis Hall Electrical Shutdown 8/20/19

CPFM Utilities and Energy have scheduled an electrical shutdown on August 20th from 4:00 am – 6:30 am at Lillis Hall to add new hardware for electrical metering.  This is part of the campus energy management campaign to capture energy use on campus.  Advance notice was sent to Facilities Liaisons on July 25th.

This will impact:

BEW4, BNW2, PSW2, 2SW2, 3SW2, BSE2, 3SE2, SWB ,PSE2, BSW2

Impact to phones, network, and card reader access:

  • Phone:   Analog phones run off the phone cabinet on DC power in the 2nd floor closet, so they should stay up.  (analog sets would include elevator phones, emergency phones, analog courtesy phones, black desk phones, fax, etc.) IP sets on folks’ desks may or may not stay up / working depending on network
  • Network:   The gateway is in the D closet 3rd floor, it’s on a UPS, and may ride out any outage.  Edge switches will be a mix, some are on electrical circuits that are not affected so will stay up, some will go down.
    Private network gateway appears to be on an affected circuit and as such will go down for the duration of the outage.
  • Building Access: There will be a controlled power shut down/power up of this system.  The main south entrance will be manned to allow access as none of the card readers in the building will be operational during this time.

Other impacted areas/equipment:

  • AHU6 Supply/Return
  • Mechanical room outlets
  • Reception outlets
  • Lighting utility
  • Room 51
  • Tunnel lighting
  • Heat meters
  • Elevator 2 lights
  • Elevator mechanical room outlet/lights
  • Elevator pit lights
  • EF-8 Fan
  • East/West Atrium outlets
  • CP-35
  • CP-31
  • CP-21
  • WH-1
  • WH-CP
  • Tunnel sump pump

For questions and concerns, please contact CPFM UE Electrical Superintendent Rick Tabor at 541-346-7511 or rtabor@uoregon.edu.